A gypsum board fire rated partition layer schedule review matches the partition types on the floor plans to the partition schedule, the referenced fire-rated designs and the wall heights on sections and elevations. Estimators do this review to confirm how many layers of board each rated wall needs, which board types the schedule calls for, and where notes or details change the standard wall. Cross-referencing partition schedules against the legends and the referenced designs helps prevent missing material layers before a bid goes out.
What is a gypsum board fire rated partition layer schedule review?
On architectural drawings, the partition schedule is the index for interior wall assemblies. A gypsum board fire rated partition layer schedule review focuses on how many layers of board are required on each side of the framing to meet the hourly rating shown for that wall type. The drawings show these requirements with partition tags that refer back to a schedule listing stud size, board type, layer count and finish requirements.
During this review, estimators also check that the scheduled partitions line up with the structural and mechanical drawings, for example at shafts, ducts and deck heights.
Why is partition schedule verification critical for drywall estimators?
Partition schedules condense complex wall constructions into short tags, and notes on the schedule sheet often modify the standard wall details.
Checking every detail in the schedule helps make sure takeoff measurements reflect the real wall heights and the right board on each face. Match studs, insulation and each board layer to the wall heights shown on building sections. For trade-specific workflows, see our drywall takeoff software page.
How do component additive methods calculate fire resistance ratings?
Rated walls normally follow a tested assembly. The International Code Council Component Additive Method guidance notes that publications from recognized testing laboratories are generally the source for fire endurance ratings of assemblies that have been tested. For wood-frame assemblies, the same guidance describes the Component Additive Method (CAM), where the calculated fire endurance equals the sum of the contribution of the fire-exposed membrane, the time to failure of the framing members and, if applicable, any additional protection from cavity insulation or reinforcement of the membrane.
The American Wood Council CAM FAQ says Section 722.6 of the 2012 International Building Code provides the basis for this approach and limits it to a maximum fire resistance rating of one hour. In the AWC example of a one hour interior wall, a single layer of 5/8-inch Type X gypsum board is assigned 40 minutes and 2x4 wood studs are assigned 20 minutes, for a total of 60 minutes.
Layer count matters in these calculations. The ICC guidance states that where two layers of panel materials, such as gypsum wallboard or plywood, are fastened to studs or joists separately, their combined effect is greater than the sum of their individual contributions to the fire endurance rating. In its table of assigned membrane times, 1/2 inch gypsum board is assigned 15 minutes, 1/2 inch Type X gypsum board 25 minutes and 5/8 inch Type X gypsum board 40 minutes. Price the layers and board types a rated partition calls for, and send any proposed substitution back to the design team.
What details should you verify in a multi-layer drywall assembly schedule?
During a schedule review, check each rated partition against the UL or GA design number referenced in the drawings or project manual. Key items to confirm include:
- Board type and thickness for each layer on each side of the framing.
- Fastener type, length and spacing for base and face layers, as listed in the referenced design.
- Board orientation and joint treatment.
- Resilient channels or sound isolation clips, and whether the referenced design includes them.
- Wall termination heights, such as to the underside of deck or just above the ceiling.
For wood-frame walls using CAM, the ICC guidance notes that on walls, gypsum board shall be installed with the long dimension parallel to framing members with all joints finished, although 5/8 inch Type X gypsum wallboard may be installed horizontally with the horizontal joints unsupported. Its recommended fastener schedule for wall assemblies is Type S or W screws with a minimum 1.5 inch penetration into the wood member at 7 inches o.c.
How can digital takeoff software assist in reviewing drywall partition schedules?
Estimators traditionally cross-reference floor plans against partition legends by hand, sheet by sheet. With EstimatorAI, you can upload the PDF plan set and specifications and ask which partition types appear on a sheet or what a tag's schedule entry calls for, then check each answer against the drawings before you count layers.
Organizing partition types this way lets estimators compare layer counts and wall heights side by side with the schedule notes. See the EstimatorAI features page for what the product does. EstimatorAI starts with a 7-day free trial, card required, then $79/month. You can review all subscription options on the pricing page.
Frequently Asked Questions
How much time does CAM assign to 5/8-inch Type X gypsum board?
In the ICC Component Additive Method table of assigned membrane times, 5/8 inch Type X gypsum board is assigned 40 minutes. CAM applies to wood-frame assemblies, and the AWC notes the IBC limits the method to a maximum rating of one hour.
How does the Component Additive Method calculate assembly fire ratings?
The ICC guidance explains that the calculated fire endurance equals the sum of the contribution of the fire-exposed membrane, the time to failure of the framing members and, if applicable, any additional protection from cavity insulation or reinforcement of the membrane. Two layers fastened separately count for more than the sum of their individual contributions.
What architectural schedule notes affect drywall layer quantities?
Notes on wall termination heights, shaft enclosures, damper framing and sound isolation can change how much board each partition needs. Review the general schedule notes along with the partition graphics to capture all required board layers.
How do estimators verify partition tags on construction plans?
Estimators compare floor plan wall symbols against the architectural partition schedule legend. They check stud sizes, wall heights on sections and elevations, and board layer counts on each side of the stud before calculating square footage totals.
Sources
Try EstimatorAI free for 7 days
Upload your PDF plans and get AI takeoff help with quantities you can check against the sheets. 7-day free trial, card required. Then $79/month, cancel anytime.
Start your 7-day free trial7-day free trial, card required. Then $79/month, $149/quarter or $499/year. Cancel anytime.