Masonry Control Joint Locations and Sealant Details Guide

Learn movement joint placement and sealant depth rules for concrete masonry and brick veneer based on industry technical standards.

Start your 7-day free trial

7-day free trial, card required. Then $79/month, $149/quarter or $499/year. Cancel anytime.

Masonry control joint locations and sealant details decide where a wall is allowed to move and how that joint stays sealed. On a bid set, the joints show up on exterior elevations, wall sections, typical details, and specification notes, so an estimator has to read all of them together. Concrete masonry and clay brick need different joints: control joints in concrete masonry handle shrinkage, while expansion joints in brickwork handle expansion. This guide covers where each type goes, how far apart the joints can be, and what the sealant detail should include, based on NCMA and Brick Industry Association technical guidance.

Where should masonry control joints be located in wall assemblies?

Control joints in concrete masonry unit (CMU) walls are placed at points of stress concentration, such as changes in wall thickness, pipe or duct chases, and pilasters, as detailed in NCMA TEK 10-2C. TEK 10-2C also lists changes in wall height, locations above movement joints in foundations and floors, locations above and below movement joints in roofs and floors that bear on the wall, and one or both sides of door and window openings. The TEK describes a control joint as a vertical plane of weakness, made by replacing all or part of a vertical mortar joint with a backer rod and sealant, and it notes that joint reinforcement should be stopped at control joints unless it is needed for structural purposes.

Control joint placement near corners should be within half of the allowable joint spacing, based on the Wire-Bond PVC control joint installation instructions. The same instructions list wall openings, changes in wall height or thickness, construction joints in foundations, roofs and floors, and wall intersections as typical locations, and they note that walls without openings are divided into a series of isolated panels.

How are control joints handled at wall openings?

Openings are a weak point because cracking follows the planes of greatest weakness. For an opening up to 6 ft (1.83 m) wide that is not wrapped with reinforcement, TEK 10-2C places a control joint at one side of the opening. When a slip plane under the bond beam is used for openings larger than 6 ft (1.83 m), TEK 10-2C recommends control joints on both sides of the opening. The TEK also shows an alternative: if the opening is fully surrounded by reinforcement, the control joints can be placed away from the opening. For takeoff, that means the joint count around windows and doors depends on which opening detail the drawings actually use, so check the lintel and jamb details before counting.

How do you space control joints and expansion joints in masonry?

Concrete masonry and clay brick move in opposite directions over time, so the spacing rules come from different documents. The Brick Industry Association Technical Note 18A says a control joint tends to widen as concrete masonry shrinks, while an expansion joint in brickwork partially closes as the brick expands, and it warns that the joint types should not be used interchangeably.

Table 1 of TEK 10-2C limits the distance between control joints in above grade exposed concrete masonry walls to the lesser of a length to height ratio of 1.5 to 1 or 25 ft (7.62 m). Those values assume horizontal reinforcement with an area of at least 0.025 square inches per foot of wall height, and the TEK notes that local experience may justify adjusting the spacing. In the TEK's worked example, a 20 ft tall wall that is 100 ft long gets a maximum spacing of 25 ft, because 25 ft is less than the 30 ft that the 1.5 to 1 ratio would allow.

Vertical expansion joints in brick veneer without openings should be spaced at most 25 ft (7.6 m) on center according to the Brick Industry Association. For brickwork with multiple openings, TN 18A recommends a reduced spacing of no more than 20 ft (6.1 m). TN 18A also lists corners, offsets and setbacks, wall intersections, changes in wall height, changes in the wall backing system, and changes in how the veneer is supported. At corners, the note prefers a joint within about 2 ft of the corner, and it says the distances from the corner to the first joint in each wall should add up to no more than the straight-wall spacing. Where a brick wythe is combined with a concrete masonry wythe, TN 18A places expansion joints in the brick and control joints in the concrete masonry, and the two do not have to line up.

What are the essential sealant details for masonry control joints?

TN 18A calls for joint sealants that comply with ASTM C920, Grade NS, Use M, and notes that silicone sealants are generally recommended for brickwork, with polyurethanes and polysulfides also used successfully. The note also recommends field adhesion testing on the project substrates to confirm bond and decide whether a primer is needed.

Sealant depth should equal approximately one-half the expansion joint width, with a minimum sealant depth of 1/4 in. (6.4 mm), as outlined by the Brick Industry Association. TN 18A calls for a circular foam backer rod sized about 25 percent larger than the joint width, and the sealant must not adhere to the backer rod. For concrete masonry control joints, TEK 10-2C gives the same rule of thumb: sealant depth of approximately one-half the joint width to reduce sealant strain.

How do estimators verify control joint quantities from project plans?

Start with the exterior elevations, where joints are often drawn as vertical lines, then check wall sections, typical details, and the specification for joint types, sealant, and backer rod. Look for general notes that set a maximum spacing instead of drawing every joint, and compare that spacing with the openings, corners, and height changes on each elevation. TN 18A says vertical expansion joints should extend to the top of the brickwork, including parapets, so measure joint lengths to the top of the masonry rather than to the roof line. Keep control joints in CMU and expansion joints in brick as separate line items, since the details and sealant requirements can differ.

EstimatorAI can help with this first pass. You upload the PDF plans and specifications, get first-pass quantities, and ask plain-English questions such as where control joints are shown or what sealant the specification calls for. Every answer still needs your review against the drawings, and results can be exported to Excel. See how this works for masonry plan and spec review, browse plan review by division, or read about concrete takeoff software and takeoff to Excel.

When reviewing bids, confirm sealant products, backer rod sizes, joint fillers, and the labor for joint preparation. EstimatorAI offers a 7-day free trial, card required, then $79/month. See EstimatorAI pricing for plan details.

Frequently Asked Questions

Where should control joints be placed in concrete masonry walls?

NCMA TEK 10-2C places control joints at changes in wall height, at changes in wall thickness such as pipe and duct chases and pilasters, above movement joints in foundations and floors, near one or both sides of door and window openings, and within half the control joint spacing of corners and wall intersections.

What is the maximum spacing for masonry control joints?

For above grade exposed concrete masonry walls, TEK 10-2C Table 1 uses the lesser of a 1.5 to 1 length to height ratio or 25 ft. For brick veneer expansion joints, the Brick Industry Association recommends no more than 25 ft on center without openings and no more than 20 ft with multiple openings. Project specifications and the engineer's details govern.

What is the difference between a control joint and an expansion joint in masonry?

A control joint is a plane of weakness in concrete masonry that lets shrinkage cracking happen at a planned location, and it tends to widen as the masonry shrinks. An expansion joint in brickwork is an open joint that partially closes as the brick expands. The Brick Industry Association says the two types should not be used interchangeably.

How deep should sealant be in a masonry expansion joint?

The Brick Industry Association recommends a sealant depth of about one-half the joint width, with a minimum of 1/4 in., installed over a circular foam backer rod that the sealant does not stick to.

How do estimators calculate sealant linear footage for masonry joints?

Count the vertical joints on each exterior elevation, measure each to the top of the masonry (brick expansion joints extend through parapets), and add any horizontal joints shown in the details. Check general notes for a maximum spacing that adds joints not drawn on the elevations, and review the result against the drawings before pricing.