Plumbing Cleanout Access in Fixture and Riser Drawings Guide
Learn how to locate and count plumbing cleanout access points across fixture details and riser diagrams for material takeoffs.
7-day free trial, card required. Then $79/month, $149/quarter or $499/year. Cancel anytime.
Plumbing cleanout access in fixture and riser drawings shows where service openings are planned so drainage lines can be cleaned. Estimators review these locations on floor plans, architectural elevation sheets and riser diagrams to count cleanout fittings, extensions and access covers before pricing a plumbing takeoff. Cross-checking the sheets against each other helps confirm that every cleanout the code calls for is carried in the estimate.
Where is plumbing cleanout access required on plumbing plans?
When reading plumbing sheets, estimators compare the cleanouts shown on the drawings with the code requirements for the project. According to PHCPPros code analysis, drainage stack designs require a cleanout access point at the base of each waste or soil stack. Base-of-stack cleanouts give drain cleaning equipment a way into the vertical risers.
Long horizontal drainage runs also need cleanouts along their length. The IPC section quoted by PHCPPros requires cleanouts on horizontal drains within buildings located not more than 100 feet apart. Estimators check total developed piping lengths on plan views so intermediate cleanouts are not missed.
Specific fixture connections also demand dedicated cleanout access. The same IAPMO code publication states that a cleanout shall be installed above the fixture connection fitting serving each urinal, regardless of the location of the urinal in the building. IAPMO explains that this gives access for mechanically cleaning the drain line without having to remove the urinal from the wall. The same UPC section also calls for a cleanout at the upper terminal of each horizontal drainage pipe.
How do fixture drawings and riser diagrams show cleanout locations?
On plumbing floor plans, cleanouts are usually shown with a symbol and a tag such as CO or WCO. Check the plumbing legend on each set for the exact symbols and abbreviations the engineer used before counting.
Riser diagrams show vertical drainage stacks and the cleanout fittings on them, but they do not show exact architectural wall locations. Estimators cross-reference riser diagrams with floor plans and interior wall elevations to determine physical mounting positions and finish requirements.
Concealed piping requires extensions to bring the cleanout plug to an accessible surface. As noted in PHCPPros drainage standards, cleanouts on concealed piping must be extended through and terminate flush with the finished wall, floor or ground surface, or be extended to the outside of the building. Wall elevations and plumbing details show which access cover, access door or floor plate is specified at each location.
Once the cleanout locations are marked up, estimators can upload the plan PDFs to EstimatorAI to get first-pass quantities and ask plain-English questions about the drawings, then review the results and export them to Excel. For trade-specific context, see the plumbing takeoff software page and the plumbing division overview.
What plumbing code rules govern cleanout placement and clearances?
Plumbing codes set minimum clearances in front of cleanouts so drain cleaning equipment can be used. Under IPC 708.8, as quoted by PHCPPros, cleanouts on 6-inch and smaller pipes need a clearance of not less than 18 inches for rodding, and cleanouts on 8-inch and larger pipes need not less than 36 inches. Estimators review wall chases and equipment rooms to check that access panels and surrounding work leave that space.
Changes of direction in drainage lines also trigger cleanout requirements. IPC 708.3.3 requires a cleanout at each change of direction greater than 45 degrees in the building sewer, building drain and horizontal waste or soil lines. The UPC adds a cleanout for each aggregate horizontal change of direction exceeding 135 degrees, according to the IAPMO code spotlight on UPC 707.4.
Which code applies depends on the jurisdiction, so confirm the adopted plumbing code and any local amendments before relying on a count.
How do estimators perform material takeoffs for cleanout assemblies?
A complete cleanout takeoff includes more than the pipe fitting. Estimators break each cleanout assembly into its material components so nothing is left off the estimate.
Components to check for each cleanout include:
- The cleanout fitting, such as a wye-type fitting where a cleanout extension turns
- The cleanout plug, which PHCPPros notes must have raised square or countersunk square heads under the IPC
- Any extension needed to reach the finished wall, floor or ground surface
- The access cover, cover plate or access door
Estimators begin by marking every cleanout tag on the floor plans. Next, they check the riser diagrams for base-of-stack cleanouts that might not be tagged on the plans. Finally, they review fixture details, such as urinal details, for cleanouts above the fixture connection.
EstimatorAI can give a first-pass count to start from, and every quantity should still be checked against the drawings. For more on organizing quantities, read the takeoff to Excel guide.
To test EstimatorAI on your plumbing project plans, start with a 7-day free trial, card required, then $79/month.
Frequently Asked Questions
What is a plumbing cleanout on construction drawings?
A plumbing cleanout is an access opening with a removable plug on a drainage pipe so the line can be cleaned. Drawings usually show cleanouts with a symbol and tag on floor plans, elevations and riser diagrams. Estimators count these symbols to work out the fittings, extensions and access covers to include in the estimate.
Why is cleanout access needed above a urinal connection?
The UPC requires a cleanout above the fixture connection fitting serving each urinal. IAPMO explains that this gives access for mechanically cleaning the drain line without having to remove the urinal from the wall. Estimators check urinal detail drawings so these cleanouts are included in the takeoff.
Where must cleanouts be placed on vertical drainage stacks?
A cleanout shall be provided at the base of each waste or soil stack under IPC 708.3.4. Estimators identify stack bases on plumbing riser diagrams so those cleanouts are counted even when the floor plans do not tag them.
How far apart should cleanouts be on long horizontal drain pipes?
The IPC requires cleanouts on horizontal drains within buildings located not more than 100 feet apart. The UPC requires a cleanout for each 100 feet, or fraction thereof, of a run more than 100 feet in total developed length. Estimators measure continuous horizontal runs on plan views to count the inline cleanouts needed.
What clearance is required in front of a cleanout fitting?
Under IPC 708.8, cleanouts on 6-inch and smaller pipes need a clearance of not less than 18 inches for rodding, and cleanouts on 8-inch and larger pipes need not less than 36 inches. Check the adopted code for the project, because the UPC sets its own clearances. Estimators review wall elevations and layouts to confirm that access covers have that space in front of them.
What is the difference between a floor cleanout and a wall cleanout?
Both are cleanouts on concealed piping extended to a finished surface: a floor cleanout terminates flush with the finished floor, and a wall cleanout terminates flush with the finished wall, usually behind an access cover. Where a cleanout is in an area subject to vehicular traffic, the IPC requires a cover plate, access door or cleanout of an approved type designed and installed for this purpose. Cleanouts with plate-style access covers must have corrosion-resisting fasteners.
Sources